V:Kit Software Platform with GC Protocols
A comprehensive set of over 40 test templates with SOPs for GC and GCMS systems with liquid and headspace injectors, and FID, ECD, TCD and MS detection.
V:Kit's flexible, protocol designer tools allow users to build protocols suitable for any GC configuration, irrespective of the number of inlets, detectors and samplers.
The test templates are delivered and executed by V:Kit software. Tests can be assembled into user-defined protocols to deliver qualifications on any system configuration.
Default setpoints and limits are supplied and are also user definable within your own customised protocols.
Once authorised, the protocol is secured and version control is enabled.
Standard Operating Procedures
Each test design contains a SOP which is directly accessed from the software. They are centrally distributed and are only accessible by authorised users. Full version control is enabled, and obsolete versions automatically archived, preventing use of out of date procedures.
Each SOP provides instructions on how to execute the test and documents the formulae and calculations used in the data evaluation. This assists the process of data checking by Quality Assurance or external auditors.
Certificates of Analysis
COAs are directly accessed from the software, which automatically extracts and embeds the analytical data directly into the test protocol. This avoids transcription errors and prevents accidental use of out of date materials.
The COA of a batch of a standard used in a OQ/PQ test can be electronically attached to the qualification report. So no more photocopies or poor quality scans….
V:Kit COAs follow ISO guidelines regarding certified values, intended use, homogeneity, storage, hazard and quality information.
Operational Qualification Test Templates
- Inlet Flow - accuracy and precision (Split, Purge, Column flow)
- Inlet Temperature
- Inlet Pressure
- Inlet Pressure Decay / Leak Test
- Column Oven Temperature Accuracy with Precision
- Response Linearity
- Injection Precision and Carryover
- Detector Flow - accuracy and precision (H2, Air, Make-Up)
- Detector Temperature
- Signal-to-Noise
- Noise and Drift
- Response Linearity
- Injection Precision and Carryover
- Detector Flow - accuracy and precision (Make-Up, Reference Gas)
- Signal-to-Noise
- Noise and Drift
- Injection Precision and Carryover
- Detector Flow - accuracy and precision (Make-Up, Purge Gas)
- Signal-to-Noise
- Noise and Drift
- Mass Accuracy
- Mass Precision
- Signal-to-Noise
- Noise and Drift
- Interface Temperature
- Injection Precision
- Injection Precision and Carryover
- Headspace Injection Precision
- Headspace Temperature (Vial Heater/Sample Oven, Sample Loop, Transfer Line, Syringe)
- Headspace Pressure and Vent Valve Check
Additional Test Templates (optional)
- GC/GCMS IQ
- GC PQ - FID
- Agilent 6890/7890 PM
- Agilent ALS PM
- Agilent HS PM